| Height―ground floor to roof | 3282 feet (1000.8 m) |
| Number of stories | 278 |
| Building uses (assumed) | Hotel, office and residential |
| Frame materials | Concrete structure |
| Typical floor live load | 3 kn/m2 (60 psf) |
| Basic wind velocity (100 years returned period for Qatar, wind load considered for Qatar) | 41.67 m/sec (150 km/hour) |
| Allowable Sway (Drift) [6] -(commentary appendix C-Sec: CC.1.2 ASCE 7-10) | H/500 (H = height of the structure) |
| Allowable sway at top of author’s tower | 1000.8 m/500 = 2001.6 mm (6’-6”) |
| Sway of the tower at top for dynamic analysis | 1930 mm (6’ - 4”) |
| Type of structure | Arrangements of concrete shear walls and beams for Tier-1, Tier-2, Tier-3 and Tier-4. Tier-5 is the frame structure |
| Foundation type | Future assignment |
| Typical floor height | 3.6 m |
| Floor type | R.C.C. Slab |
| Shear wall spacing | 12 m, 9 m & 6 m c/c |
| Core area | Column-beam framing |
| Shear wall thicknesses at ground floor | 1.6 m, 1.5 m, 1.4 m & 1.3 m, gradually decreasing the thicknesses toward top |
| Typical beam sizes | Depth 0.8 m, width 1.1 m & 1.2 m |
| Column spacing | 6 m (20 feet) c/c |
| Column sizes at base | 1.5 m × 1.5 m |
| Covered area at base by shear walls & columns | 14.53% |
| Concrete strength | Shear walls & columns 80 MPa, beams & slab 40 MPa |
| Aspect ratio (building height/least length at base) | 9.8:1 |