| Indicator | UCL | GHR/Sendwe |
| Respiratory reanimation |
|
|
| Number of devices for the administration of medical fluids (cylinders, pressure regulators, masks, probes, nebulizers) and an emergency oxygen cylinder | 5 | 2 |
| Number of sets of face masks, various sizes | 4 | 2 |
| Number of sets of oropharyngeal cannulas of different sizes | 0 | 0 |
| Number of manual insufflators associated with an age-appropriate oxygen enrichment tank | 4 | 2 |
| Number of intubation trays | 0 | 0 |
| Number of intubation probes | 0 | 0 |
| Number of difficult intubation algorithms. | 0 | 0 |
| Number of pulse oxygen saturation monitors | 1 | 0 |
| Number of expiratory CO2 capnography monitors | 0 | 0 |
| Number of automatic ventilators | 0 | 0 |
| Number of electric suction units | 1 | 0 |
| Number of manual rescue suction devices | 1 | 1 |
| Number of devices for measuring peak expiratory flow | 0 | 0 |
| Number of thoracic drainage devices | 0 | 0 |
| Cardiovascular reanimation |
|
|
| Number of electrocardioscopic monitors | 0 | 0 |
| Number of automatic blood pressure measuring devices | 0 | 0 |
| Number of manual blood pressure measuring devices | 1 | 0 |
| Number of defibrillators with pediatric paddles | 0 | 0 |
| Number of electrocardiogram machines | 0 | 0 |
| Number of electric syringe pumps | 1 | 0 |
| Number of equipment for vascular and intraosseous access | 10 | 10 |
| Number of transfusion kits | 5 | 4 |
| Number of instantaneous hemoglobin measurement devices | 1 | 1 |