Unit process | Parameter | Water reuse (WR) | Desalination |
Coagulation | FeCl3 dose, mg/L | No | 5 |
Pretreatment |
| MBR or CAS-TF effluent | Multimedia filtration |
Anti-scalant addition | Dose, mg/L | 2 | 5 |
Reverse osmosis (RO) | Stages, number | 2 | 2 |
Recovery, % | 75 | 50 | |
Flux, L/m2/h | 20 | 13 | |
Feed pressure, bar (psi) | 13.6 (200) | 68 (1000) |