Basic Event

Code

Failure Rate

Basic Event

Code

Failure Rate

Failure of signal connector for battery system

eb1

λeb1 = 0.051

Failure of PCB for slave controller

eb9

λeb9 = 0.005

Failure of power connector for battery system

eb2

λeb2 = 0.085

Failure of SMCs for slave controller

eb10

λeb10 = 0.018

Failure of battery cells module

eb3

λeb3 = 1.002

Failure of communication chip for slave controller

eb11

λeb11 = 0.004

Failure of signal connectors for battery cells

eb4

λeb4 = 0.011

Failure of fuse for main circuit

eb12

λeb12 = 2.058

Failure of fastening screw for battery module

eb5

λeb5 = 0.001

Failure of relay for main circuit

eb13

λeb13 = 0.272

Failure of PCB for master controller

eb6

λeb6 = 0.013

Failure of current sensor

eb14

λeb14 = 0.004

Failure of SMCs for master controller

eb7

λeb7 = 0.018

Failure of voltage sensor

eb15

λeb15 = 0.018

Failure of master chip

eb8

λeb8 = 0.252

Failure of temperature sensor

eb16

λeb16 = 0.006