Basic Event | Code | Failure Rate | Basic Event | Code | Failure Rate |
Failure of signal connector for battery system | eb1 | λeb1 = 0.051 | Failure of PCB for slave controller | eb9 | λeb9 = 0.005 |
Failure of power connector for battery system | eb2 | λeb2 = 0.085 | Failure of SMCs for slave controller | eb10 | λeb10 = 0.018 |
Failure of battery cells module | eb3 | λeb3 = 1.002 | Failure of communication chip for slave controller | eb11 | λeb11 = 0.004 |
Failure of signal connectors for battery cells | eb4 | λeb4 = 0.011 | Failure of fuse for main circuit | eb12 | λeb12 = 2.058 |
Failure of fastening screw for battery module | eb5 | λeb5 = 0.001 | Failure of relay for main circuit | eb13 | λeb13 = 0.272 |
Failure of PCB for master controller | eb6 | λeb6 = 0.013 | Failure of current sensor | eb14 | λeb14 = 0.004 |
Failure of SMCs for master controller | eb7 | λeb7 = 0.018 | Failure of voltage sensor | eb15 | λeb15 = 0.018 |
Failure of master chip | eb8 | λeb8 = 0.252 | Failure of temperature sensor | eb16 | λeb16 = 0.006 |