Test

VMA Type SCC

Powder Type SCC

Permissible Limits

Slump Flow diameter (mm)

690

680

650 - 800

V-Funnel Time T0 (Sec)

11.2

8.2

6 - 12

V-Funnel at T5 minute (Sec)

13.8

10.9

≤T0 + 3

L-Box T20 cm (Sec)

1.2

0.89

1 ± 0.5

L-Box T40 cm (Sec)

2.3

2.34

2 ± 0.5

L-Box Blocking Ratio (H2/H1)

0.8

0.86

0.8 - 1.0