Case/Name

Diagnosis for ANSI/IEEE C57.104

Diagnosis for

Program out

Repair State

H2

CH4

C2H6

C2H4

C2H2

C2H2/C2H4

C2H4/C2H6

CH4/H2

C1

0

0

0

0

0

1

0

1

0

N

C2

0

0

0

0

1

1

1

1

1

Ac

C3

0

0

0

0

1

1

1

0

1

Ac

C4

0

0

0

1

1

1

1

1

1

Pd

C5

0

0

0

1

0

0

1

1

1

Ac

C6

0

0

1

1

0

0

1

1

1

Pd

C7

0

0

0

1

0

0

1

1

1

Pd