The disturbance type

The experiments times

The correct ratio of identifying the disturbance type

The average error of the parameters evaluation

The voltage sag

100

100%

2.12%

The fluctuation and flicker

100

99%

3.01%

The harmonics

100

98%

2.00%

The oscillatory transients

100

98%

2.45%

The interharmonics

100

97%

6.33%

The harmonics + The voltage sag

100

100%

3.58%

The harmonics + The fluctuation and flicker

100

96%

2.99%

The harmonics + The oscillatory transients

100

100%

3.07%

The fluctuation and flicker + The voltage sag

100

100%

4.28%

The fluctuation and flicker + The oscillatory transients

100

100%

4.14%

The interharmonics + The voltage sag

100

100%

2.78%

The interharmonics + The oscillatory transients

100

99%

2.99%

The interharmonics + The fluctuation and flicker

100

96%

3.46%

The interharmonics + The harmonics

100

97%

2.53%

The interharmonics + The harmonics + The voltage sag

100

99%

4.01%

The interharmonics + The harmonics + The voltage sag + The fluctuation and flicker

100

98%

3.98%