Plot number 20: | ||
Peak evapotranpiration | 8 | mm∙day−1 |
Wetted area per plant: | 0.45 | m2 |
Relevant depth of roots for blueberry crops: | 0.2 | m |
Wetted volume of soil: | 0.09 | m3 |
Water content at 10 cb: | 32.4 | % |
Water content at 20 cb: | 22.5 | % |
Available percentage of water range for that interval: | 9.9 | % |
Volume of water to be replaced: | 8.91 | liters∙plant−1 |
Flow per hour for 1 liter hour drippers each 30 cm, two drip lines per row: | 6 | liters∙hour−1 |
Dally irrigation time to supply water requirements: | 89.1 | minutes |
Shaded area per plant: | 1.53 | m2 |
Daily demand for peak according with shaded area: | 12.24 | liters∙plant−1∙day−1 |
Minimum operations per day to supply water demand: | 1.3 | Daily operation |