| Features | Monte Goa A | Monte Goa B | |
| Energy | Gross head | 444 m | 409.3 m |
| Net head | 427.3 m | 401 m | |
| Installed power | 15,000 kW | 15,000 kW | |
| Mean annual production | 32.9 GWh | 32.9 GWh | |
| Upstream Reservoir | Normal water level | 444 m | 444.5 m |
| Minimum operation level | 432.5 m | 432.5 m | |
| Max. reservoir height | 11.5 m | 12 m | |
| Net reservoir volume | 183,800 m3 | 194,700 m3 | |
| Downstream Reservoir/Intake | Type | onshore water intake | reservoir |
| Normal water level | 0 | 35 | |
| Minimum operation level | −10 | 24 | |
| Max. reservoir height | - | 11 | |
| Net reservoir volume | - | 221,000 m3 | |
| Hydraulic Circuit | Cross section | 1200 | 1400 |
| Length | 1900 m | 1870 m | |
| Power House | Type | underground | underground |
| Turbines | 2 × Francis reversible vertical axis | 2 × Francis reversible vertical axis | |
| Axis elevation | −40.0 m | −16 m | |
| Max. generating flow | 4.2 m3/s | 4.4 m3/s | |
| Max. pumping flow | 3.0 m3/s | 3.2 m3/s | |
| Net head | 427.3 m | 401 m | |
| Transmission Line | Voltage | 60 kV | 60 kV |
| Length | 15 km | 10.58 km | |
| Total Cost Estimate | 32 M€ | 37.4 M€ | |