Current work

Previous work (Al-Taie et al., 2013)

Location

Bearing capacity KPa

Avg. worst

Suggestions

Bearing capacity KPa

Suggestions

Mosul

177

77

Use shallow foundation (continues, spread and mat is to be used if the basement is required)

300

Any type of shallow foundation

Baghdad

125

68

Shallow foundation (spread and mat) is suitable in use in some parts of Baghdad region for buildings with not more than five floors

70

Mixed 2 kinds of foundation (raft and continuous)

Basrah

84

24

The mat foundation is the suitable type for low buildings

50

Raft foundation