| Experimental run | Inputs | Responses | |||
| Flow rate (lit/min) | HTF inlet temp (THTF) (˚C) | PCM capsule shape | Charging time (min) | Discharging time (min) | |
| 1 | 2 | 60 | 1 | 10 | 140 |
| 2 | 2 | 60 | 2 | 32 | 140 |
| 3 | 2 | 60 | 3 | 18 | 100 |
| 4 | 2 | 58 | 1 | 14 | 100 |
| 5 | 2 | 58 | 2 | 34 | 120 |
| 6 | 2 | 58 | 3 | 18 | 80 |
| 7 | 2 | 56 | 1 | 16 | 100 |
| 8 | 2 | 56 | 2 | 36 | 100 |
| 9 | 2 | 56 | 3 | 18 | 80 |
| 10 | 4 | 60 | 1 | 08 | 140 |
| 11 | 4 | 60 | 2 | 28 | 140 |
| 12 | 4 | 60 | 3 | 12 | 100 |
| 13 | 4 | 58 | 1 | 11 | 100 |
| 14 | 4 | 58 | 2 | 32 | 120 |
| 15 | 4 | 58 | 3 | 18 | 80 |
| 16 | 4 | 56 | 1 | 16 | 100 |
| 17 | 4 | 56 | 2 | 32 | 100 |
| 18 | 4 | 56 | 3 | 18 | 80 |