Operation | Consumption | Time | Number of activities during Tfall = 20 min |
Data Transmission to ground receiver | −30 dBm | 1 s | 40 (1 transmission every 30 seconds) |
Tranceiver consumption while it is on | 3 mA | 1 s | 40 (1 every 30 seconds) |
Accelerometer sensor measure | 0.15 mA | 10 ms | 12,000 (1 every 0.1 s) |
Temperature sensor measure | 3.6 mA | 10 ms | 600 (1 every 2 s) |
Pressure sensor measure | 3 mA | 10 ms | 600 (1 every 2 s) |
Humidity sensor measure | 1 mA | 10 ms | 600 (1 every 2 s) |
Sensors in stand by (low power mode) | 120 μA | Remaining time during Tfall |