Precondition—Delete the pole of | ||
ID | Input | Expected output |
PQMS2-ACF-UNI-TC100 | Start the XAve-R chart with default setting and inspection data, and values of default setting are given with “strSetting [20] = {220, 750, 0.60, 0.46, 10.0, 220, 1000, −530, 1000, 11, 30, 820, 1.25, 0, 1500, 130, 10.0, 0.75, −340, 4}”, and inspection data is the data batch of “2018_01_01 INSPDAVA2_1 4” with 80 values. | Display precisely with correct layout and no prompt of error information. |
PQMS2-ACF-UNI-TC010 | Start the “supervision/tolerance setting” sheet from the XAve-R window interface of the XAve-R chart, and input “0.60” in the EidtBox “Supervising or tolerance lower limit”, and input “0.46” in the EidtBox “Supervising or tolerance up limit”, and input “4” in the EidtBox “Sampling volume”, and click button “OK” finally. | Update displaying precisely with correct layout and no prompt of error information. |
PQMS2-ACF-UNI-TC001 | Start the “Coefficient setting” sheet from the XAve-R window interface of the XAve-R chart interface, and input “10.0” in the EidtBox “Vertical coordinate magnitude coefficient”, and input “1.25” in the EidtBox “Total magnitude coefficient”, and input “10.0” in the EidtBox “R vertical coordinate magnitude coefficient”, and input “0.75” in the EidtBox “R total magnitude coefficient”, and input “0” in the EidtBox “Update velocity”, and input “1500” in the EidtBox “history displaying space”, and click button “OK” finally. | Update displaying precisely with correct layout and no prompt of error information. |
PQMS2-ACF-UNI-TC020 | Start the “Layout parameter setting” sheet from the XAve-R window interface, and input “11” in the EidtBox “Caption offset”, and input “1000” in the EidtBox “Right space”, and input “820” in the EidtBox “Limits offset”, and input “1000” in the EidtBox “y offset”, and input “220” in the EidtBox “x offset”, and input “30” in the EidtBox “Judgment output”, and input “−530” in the EidtBox “Coordinate axle offset”, and input “750” in the EidtBox “Ry offset”, and input “220” in the EidtBox “Rx offset”, and input “130” in the EidtBox “R judgment output”, and click button “OK” finally. | Update displaying precisely with correct layout and no prompt of error information. |
PQMS2-ACF-UNI-TC101 | After TC100, click menu item “Monitoring of XAve-R—Forward” or toolbar “Monitoring forward”. | Display next chart precisely with correct layout and no error prompt. |
PQMS2-ACF-UNI-TC102 | After TC101, click menu item “Monitoring of XAve-R—Backward” or toolbar “Monitoring backward”. | Display previous chart precisely with correct layout and no error prompt. |
PQMS2-ACF-UNI-TC103 | Click menu item “Monitoring of XAve-R—Update” or toolbar “Monitoring Update”. | Update displaying of current chart precisely with correct layout and no error prompt. |