Morphot ectonic Parameter

Unit

Formula

Result

Hypsometric Integral (HI)

-

HI = (Mean Elevation − Minimum Elevation)/ (Maximum Elevation − Minimum Elevation)

Range = 0.24 - 0.84

Average = 0.49

Sinuosity Index (SI)

-

SI = (Length of Stream Channel)/(Length of Straight − Line Distance)

1.37

Asymmetry Factor (Af)

-

100 * (Ar/At)

67.29