[Ref.] Year | Configuration | No. of active building block used | No. of passive component | Grounded passive component | Component constraints | Availability of LP, HP, BP, notch and AP response | Is the gain of input signa such as 2Iin And 3Iin required to get filter responses | Independent control of | Electronic tunability | |
f0 and BW | f0 and Q0 | |||||||||
[13] 2007 | 3 input | 2 CDTA | 2 | Yes | No | Yes | Yes | Yes | No | Yes |
[14] 2010 | 3 input | 4 OTA | 2 | Yes | LP, HP, BP & Notch = No, AP = Yes | Yes | Yes | Yes | No | Yes |
[15] 2011 | 5 input | 3 CCII | 5 | No | No | Yes | No | Yes | No | No |
[16] 2011 | 5 input | 3 ICCII | 4 | No | No | Yes | No | Yes | No | No |
[17] 2011 | 4 input | 1 FDCCII | 5 | Yes | LP, BP = No, HP, Notch & AP = Yes | Yes | No | Yes | No | No |
[18] 2011 | 4 input | 2 MO-CCCII | 2 | Yes | No | Yes | No | Yes | Yes | Yes |
[19] 2011 | 3 input | 1 DVCCTA | 3 | Yes | LP, BP, HP = No, Notch & AP = Yes | Yes | No | Yes | Yes | Yes |
[20] 2011 | 3 input | 2 CCCII | 2 | Yes | No | Yes | Yes | Yes | No | Yes |
[21] 2011 | 3 input | 4 CDTA | 4 | Yes | No | Yes | No | Yes | No | Yes |
[22] 2012 | 3 input | 2 CCCCTA | 2 | Yes | LP, BP. HP, Notch & AP = Yes | Yes | No | Yes | Yes | Yes |
[23] 2013 | 3 input | 2 VDTA | 2 | Yes | LP, BP. HP, Notch & AP = Yes | Yes | Yes | Yes | Yes | Yes |
[24] 2013 | 3 input | 2 CCCII | 2 | Yes | LP, BP. HP, Notch & AP = Yes | Yes | Yes | Yes | No | Yes |
Our work | 3 input | 1 CCDDCCTA | 2 | Yes | LP, BP = No, HP, Notch & AP = Yes | Yes | No | Yes | Yes | Yes |