Time (hr) | Measured inflow (m3/s) | Measured Outflow (m3/s) | Predicted Outflow by Muskingum method (m3/s) | Predicted Outflow by Level Pool routing (m3/s) | Predicted Outflow by Modified Pul’s (m3/s) |
0 | 0 |
|
| 85 | 0 |
1 | 93 | 85 | 85 | 77 | 17 |
2 | 137 | 91 | 103 | 102 | 53 |
3 | 208 | 114 | 141 | 135 | 96 |
4 | 320 | 159 | 207 | 202 | 157 |
5 | 442 | 233 | 295 | 295 | 239 |
6 | 546 | 324 | 391 | 396 | 332 |
7 | 630 | 420 | 483 | 493 | 426 |
8 | 678 | 509 | 560 | 572 | 509 |
9 | 691 | 578 | 612 | 626 | 573 |
10 | 675 | 623 | 639 | 657 | 613 |
11 | 634 | 642 | 639 | 641 | 629 |
12 | 571 | 635 | 615 | 624 | 619 |
13 | 477 | 603 | 565 | 569 | 584 |
14 | 390 | 546 | 499 | 497 | 529 |
15 | 329 | 479 | 434 | 431 | 467 |
16 | 247 | 413 | 363 | 361 | 402 |
17 | 184 | 341 | 294 | 288 | 333 |
18 | 134 | 274 | 232 | 224 | 270 |
19 | 108 | 215 | 183 | 175 | 215 |
20 | 90 | 170 | 146 | 141 | 173 |