Time (hr)

Measured

inflow (m3/s)

Measured

Outflow (m3/s)

Predicted Outflow by Muskingum

method (m3/s)

Predicted Outflow by Level Pool routing (m3/s)

Predicted Outflow by Modified Pul’s (m3/s)

0

0

85

0

1

93

85

85

77

17

2

137

91

103

102

53

3

208

114

141

135

96

4

320

159

207

202

157

5

442

233

295

295

239

6

546

324

391

396

332

7

630

420

483

493

426

8

678

509

560

572

509

9

691

578

612

626

573

10

675

623

639

657

613

11

634

642

639

641

629

12

571

635

615

624

619

13

477

603

565

569

584

14

390

546

499

497

529

15

329

479

434

431

467

16

247

413

363

361

402

17

184

341

294

288

333

18

134

274

232

224

270

19

108

215

183

175

215

20

90

170

146

141

173