Authors

Year

No.

Ventilation

Rhythm

VE

Position

Responder

Index

Techniques

Lafanechère

[12]

2006

22

MV

sinus

500cc saline

supine position

ΔABF≥15%

cABF-TEE cPP

TEE arterial BP transducer

Monnet [13]

2006

71

MV

sinus/arr

500cc saline

semi-recumbent

ΔABF≥15%

cPP cABF-TEE

arterial BP transducer TEE

Lamia [14]

2007

24

MV/SB

sinus/AF

500cc saline

semi-recumbent

ΔSVI≥15%

cVTIAo-TTE cCO-TTE

TTE TTE

Maizel [15]

2007

34

SB

sinus

500cc saline

supine position

ΔCO-TTE≥12%

cCO-TTE cSV-TTE

TTE TTE

Thiel [16]

2009

89

MV/SB

sinus/arr

500cc saline, Ringer’s lactate, HES

semi-recumbent

ΔSV≥15%

cSV-TTE

TTE(USCOM)

Monnet [17]

2009

34

MV

sinus/arr

500cc saline

semi-recumbent

ΔCI≥15%

cCI cPP

PiCCO arterial BP transducer

Biais [18]

2009

30

MV/SB

sinus

500cc saline

semi-recumbent

ΔSV-TTE≥15%

cSV cSV-TTE

Vigileo TTE

Préau [19]

2010

34

SB

sinus

500cc HES

semi-recumbent

ΔSV≥15%

cSV-TTE cPP

TTE arterial BP transducer

Guinot [20]

2011

17

MV

sinus/arr

500cc saline

semi-recumbent

ΔSV-TTE>15%

cSV-TTE cCO-TTE

TTE TTE

Liu [21]

2011

20

MV

sinus/arr

250cc saline

semi-recumbent

ΔSV≥10%

cSV

PiCCO

Wang [22]

2011

33

MV/SB

sinus/arr

500cc saline

semi-recumbent

ΔSV-TTE≥15%

cSV-TTE cSV-USCOM

TTE USCOM

Monnet [23]

2012

39

MV

sinus

500cc saline

semi-recumbent

ΔCI≥15%

cPPV cPPV-CNAP

PiCCO CNAP

García [24]

2012

37

MV

sinus/arr

500cc HES

semi-recumbent

ΔCO≥15%

cCO-TEE cPP

TEE arterial BP transducer

Monnet [25]

2013

40

MV

sinus/arr

500cc saline

semi-recumbent

ΔCI≥15%

cCI

PiCCO