Model parameter

Parameters

Values

Output power

P n = 1.1 kW

Stator voltage

U s = 220 V

Stator resistance

R s = 9.8 Ω

Rotor resistance

R r = 5.3 Ω

magnetizing inductance

L m = 0.5 H

global leakage inductance referred to the stator

L f = 0.04 H

Inertia shaft

J = 12.5 × 10 3 kg m 2

Pole number

p = 2

Number of stator turns per phase

N s = 464