Record number

Reference

CR

PRD1 %

Record 100

The proposed method (signal differences)

12.37

1.07

The proposed method (original ECG signal)

9.06

1.62

Polania et al., [15]

8.49

6.09

Lu et al., [36]

8.42

6.19

Record 107

The proposed method (signal differences)

9.79

3.12

The proposed method (original ECG signal)

8.89

4.39

Polania et al., [15]

8.19

6.05

Lu et al., [36]

8.13

6.12

Record 115

The proposed method (signal differences)

9.46

2.89

The proposed method (original ECG signal)

8.71

3.80

Polania et al., [15]

8.65

5.92

Lu et al., [36]

8.73

5.84

Record 117

The proposed method (signal differences)

9.39

1.24

The proposed method (original ECG signal)

8.61

1.89

Polania et al., [15]

7.23

2.57

Lu et al., [36]

7.23

2.57