Parabolic Trough | Storage Tank/Expansion Vessel | ||
Length of SCA | 120 m | Inlet Temperature | 290˚C |
Aperture Width of SCA | 5.76 m | Inlet Flowrate | 8.53 kg/s |
Focal Length of SCA | 1.71 m | Tank Volume | 18 m3 |
Row Spacing | 12.5 m | Fluid Specific Heat | 2.3 kJ/kg∙K |
Total Field Area | 8175 m2 | Fluid Density | 900 kg/m3 |
Inlet Temperature Solar Field | 290˚C | Super Heater | |
Cleanliness Solar Field | 0.95 | Source Side Inlet Temperature | 390˚C |
Specific Heat HTF | 2.303 kJ/kg.K | Source Side Flow Rate | 8.53 kg/s |
Wind Speed Limit for Tracking | 13.7 m/s | Overall Heat Transfer Coefficient | 8748 W/K |
Evaporator | Preheater | ||
Overall Heat Transfer Factor | 58000 W/K | Source Side Inlet Temperature | 350˚C |
Source Side Inlet Temperature | 350˚C | Load Side Inlet Temperature | 105˚C |
Load Side Inlet Temperature | 253˚C | Load Side Flow Rate | 1.93 kg/s |
Load Side Outlet Pressure | 44 Bar | Overall Heat Transfer Coefficient | 16050 kJ/kg.K |
Preheater/Sub Cooler | Condenser | ||
Hot Side Inlet Pressure | 1 Bar | Cooling Water Inlet Temperature | 20˚C |
Cold Side Inlet Temperature | 70˚C | Inlet Steam Enthalpy | 3000 kJ/kg |
Cold Side Inlet Flow Rate | 1.09 kg/s | Steam Mass Flow Rate | 1.78 kg/s |
Condensate Inlet Temperature | 100˚C | Condensate Inlet Flow Rate | 0.277778 kg/s |
Turbine | Deaerator | ||
Turbine Outlet Pressure | 1 Bar | Feed Water Inlet Temperature | 25˚C |
Turbine Inlet Flow Rate | 1.93 kg/s | Feed Water Flow Rate | 0.15 kg/s |
Turbine Inlet Enthalpy | 3000 kJ/kg | Inlet Steam Pressure | 3.46 Bar |
Design Inner Efficiency | 0.8 | Condensate Inlet Temperature | 45˚C |
Generator Efficiency | 0.98 | Condensate Inlet Flow Rate | 1.78 kg/s |