DMA considered | New Zone connection option | Qmoy (l/s) | Pumping station involved | Actual flow capacity (l/s) | Bs (m3) | Tank involved | Actual volume capacity (m3) |
All | - | 264 | S1 | 79 × 3 = 237 | 2 906 | T1 or All | 5000 or 9500 |
2 + 3 | 4 or 5 | 93 | S2 + S3 | 70 + 96 = 166 | 1 035 | T2 or T3 + T4 | 2000 or 1500 |
3 ? NZ | 1 | 22 | S2 | 35 × 2 = 70 | 237 | T3 | 1000 |
3 | 2 or 3 | 30 | S2 | 35 × 2 = 70 | 315 | T3 | 1000 |
2 | 2 or 3 | 64 | S3 | 48 × 2 = 96 | 729 | T4 | 500 |
2 + NZ | 1 | 71 | S3 | 48 × 2 = 96 | 805 | T4 | 500 |
5 | - | 32 | S4 | 35 × 2 = 70 | 377 | T5 | 500 |
4 | - | 38 | S5 | 25 × 2 = 50 | 429 | T6 + T7 | 500 |