Component

Function

1

Reservoir

Stores WLO fuel

2

Immersion heater

Preheating oil

3

Oil filters

Cleaning oil

4

Pump

Pump WLO to the atomizing nozzle

5

Flow control valves

Control the flow rates of both WLO and oxidizer

6

Nozzle

Atomize WLO fuel

7

Blower

Supply air under pressure

8

Air and fuel flow meters

Measure reactants’ flow rates

9

Transformer

Enhance ignition

10

Ignition electrodes

Ignite the mixed reactants

11

PLC logo

Monitor and control the WLO combustion process

12

Copper tubes

Provide fuel flow lines

13

Combustion chamber

Provide space for reactants’ combustion

14

Motor

Electrical drive system for various components

15

Couplings

Torque transmission from motor to pump