Section | Load combination type | N (kN) | M (kN∙m) |
| R (kN) | Meet the specification or not |
Main arch foot section | Max (T+) | −29365.16 | −6465.73 | 0.62 | −19183 | No |
Max (T−) | −29126.23 | −7978.37 | 0.52 | −55925 | Yes | |
Min (T+) | −32419.86 | −12893.72 | 0.31 | −9601 | No | |
Min (T−) | −32180.94 | −14406.35 | 0.23 | −130147 | Yes | |
L/4 main arch section | Max (T+) | −24259.57 | 5312.16 | 0.63 | −19258 | No |
Max (T−) | −23712.27 | 5301.33 | 0.62 | −18973 | No | |
Min (T+) | −27067.24 | 1605.41 | 0.92 | −28234 | Yes | |
Min (T−) | −26519.95 | 1594.58 | 0.92 | −28206 | Yes | |
Arch crown section | Max (T+) | −23311.02 | −956.59 | 0.94 | −28772 | Yes |
Max (T−) | −22631.03 | 71.72 | 0.95 | −29280 | Yes | |
Min (T+) | −25971.56 | −4515.15 | 0.72 | −22111 | No | |
Min (T−) | −25291.57 | −3486.83 | 0.79 | −24350 | No |