Severity | Alarm ID | Name | NE Type | Location Information | Additional Information | Occurred On (NT) |
Critical | 65034 | AC Power Failure | BTS3900 | Cabinet No. = 0, Subrack No. = 0, Slot No. = 19, Port No. = 0, Board Type = UPEU | RAT_INFO = UL, AFFECTED_RAT = UL, DID = NULL | 08/17/2019 17:24:46 |
Major | 65041 | Battery Fuse Break | BTS3900 | Cabinet No. = 0, Subrack No. = 0, Slot No. = 19, Port No. = 7, Board Type = UPEU | RAT_INFO = UL, AFFECTED_RAT = UL, DID = NULL | 08/17/2019 17:25:54 |
Major | 26232 | BBU Optical Module Transmit/Receive Fault | BTS3900 | Cabinet No. = 0, Subrack No. = 0, Slot No. = 1, Port No. = 0, Board Type = UBBP, Specific Problem = Receive Power Too Low | RAT_INFO = UL, AFFECTED_RAT = U, DID = NULL, Cumulative Duration(s) = 90 | 08/17/2019 17:26:25 |
Major | 25888 | SCTP Link Fault | BTS3900 | Link No. = 6, Description = NULL, Peer IP Address = 10.32.248.251, Service Type = NCP | RAT_INFO = UL, AFFECTED_RAT = U, DID = NULL | 08/17/2019 17:27:14 |
Major | 25888 | SCTP Link Fault | BTS3900 | Link No. = 7, Description = NULL, Peer IP Address = 10.32.248.250, Service Type = CCP | RAT_INFO = UL, AFFECTED_RAT = U, DID = NULL | 08/17/2019 17:27:14 |
Major | 25888 | SCTP Link Fault | BTS3900 | Link No. = 0, Description = YDE MME, Peer IP Address = 10.31.102.1, Service Type = S1-AP | RAT_INFO = UL, AFFECTED_RAT = L, DID = NULL | 08/17/2019 17:27:14 |
Major | 25888 | SCTP Link Fault | BTS3900 | Link No. = 70002, Description = DLA MME, Peer IP Address = 10.32.202.1, Service Type = S1-AP | RAT_INFO = UL, AFFECTED_RAT = L, DID = NULL | 08/17/2019 17:27:14 |
Minor | 26263 | IP Clock Link Failure | BTS3900 | Link No. = 0, Server IP Address = 10.32.101.1 | RAT_INFO = UL, AFFECTED_RAT = UL, DID = NULL, Cumulative Duration(s) = 30 | 08/17/2019 17:27:40 |
Warning | 26819 | Data Configuration Exceeding Licensed Limit | BTS3900 | - | RAT_INFO = UL, AFFECTED_RAT = L, DID = NULL | 08/17/2019 17:28:18 |
Major | 29240 | Cell Unavailable | BTS3900 | eNodeB Function Name = YDE017_Messassi, Local Cell ID = 2, Cell FDD TDD indication = FDD, Cell Name = YDE_11017_2, eNodeB ID = 11017, Cell ID = 2, Specific Problem = Insufficient license | RAT_INFO = UL, AFFECTED_RAT = L, DID = NULL, Cumulative Duration(s) = 90 | 08/17/2019 17:28:18 |
Major | 25880 | Ethernet Link Fault | BTS3900 | Cabinet No. = 0, Subrack No. = 0, Slot No. = 7, Port No. = 0, Specific Problem = Ethernet Link Fault | RAT_INFO = UL, AFFECTED_RAT = UL, DID = NULL | 08/17/2019 17:24:36 |
Major | 25880 | Ethernet Link Fault | BTS3900 | Cabinet No. = 0, Subrack No. = 0, Slot No. = 7, Port No. = 0, Specific Problem = Ethernet Link Fault | RAT_INFO = UL, AFFECTED_RAT = UL, DID = NULL | 08/17/2019 17:31:26 |
Major | 29240 | Cell Unavailable | BTS3900 | eNodeB Function Name = YDE056_Bastos_ARMP, Local Cell ID = 10, Cell FDD TDD indication = FDD, Cell Name = YDE_11056W_0, eNodeB ID = 11056, Cell ID = 10, Specific Problem = External Link Fault | RAT_INFO = UL, AFFECTED_RAT = L, DID = NULL | 08/17/2019 17:25:12 |