ID | Start state | End state | Input | Expected output |
PQMS2-SMS-UNI-TC010 | S0 | S1 | Click the menu item of “Basic Setting - Basic setting of monitoring” from the main interface. | Display the sheet of basic setting of monitoring. |
PQMS2-SMS-UNI-TC011 | S1 | S4 | No inputting operation, click the button of “Cancel” or “Shut-off” button of up-right corner in the sheet. | Cancel basic setting, and enter the system idle. |
PQMS2-SMS-UNI-TC012 | S1 | S2 | Enter the sheet again, and input data in the ComBoBox. | Display the data in the sheet. |
PQMS2-SMS-UNI-TC013 | S2 | S4 | Input correct default data in the sheet, and click the button of “Setting”. | No prompt of error information, and save the setting data. |
PQMS2-SMS-UNI-TC014 | S2 | S3 | Enter the sheet again, and input “” in all ComBoBoxes, and click the button of “Setting”. | Prompt error information. |
PQMS2-SMS-UNI-TC015 | S3 | S4 | Click the button of “OK” or “Shut-off” button of up-right corner in the prompt dialogue. | Enter the system idle. |
PQMS2-SMS-UNI-TC016 | S2 | S4 | Enter the sheet again, and click the button of “Cancel” in the sheet when inputting data. | Cancel basic setting, and enter the system idle. |
PQMS2-SMS-UNI-TC017 | S2 | S1 | Enter the sheet again, and click the button of “Default” in the sheet. | Restore default setting. |
PQMS2-SMS-UNI-TC018 | S4 | S5 | When system is idle, click “Shut-off” button of up-right corner in the system interface. | Exit. |