Sl No. | Parameter | Sub-Parameter | |||
Name | Weight | Description | Weight | ||
P1 | Linings |
|
| Possibility of internal linings in an apartment to delay the ignition of the structure and to reduce fire growth | 0.0576 |
P2 | Suppression System |
|
| Equipment and systems for suppression of fires | 0.0668 |
P3 | Fire Service | Capability Response Time Accessibility & Equipment | 0.31 0.47 0.22 | Possibility of external agencies to save lives and to prevent further fire spread | 0.0681 |
P4 | Compartmentation |
|
| Extent to which floor areas are divided into fire compartments | 0.0666 |
P5 | Structure- Separating | Integrity & Insulation Firestops at joints, intersections & concealed spaces Penetrations Combustibility | 0.335 0.28
0.24 0.13 | Heat, smoke and fire resistance of building assemblies separating fire compartments | 0.0675 |
P6 | Doors | Doors leading to escape route Doors in escape route | 0.67 0.33 | Fire and smoke separating function of doors between fire compartments | 0.0698 |
P7 | Windows |
|
| Windows and protection of windows, i.e. factors affecting the possibility of fire spread through the openings | 0.0473 |
P8 | Façade | Combustible part of façade Combustible material above windows Void | 0.41 0.30 0.29 | Facade material, suppression system etc., i.e. factors affecting the possibility of fire spread along the façade | 0.0492 |
P9 | Attic |
|
| Prevention of fire spread to and in attic | 0.0515 |
P10 | Adjacent Buildings/ Surroundings |
|
| Minimum separation distance from other building | 0.0396 |
P11 | Smoke Control System |
|
| Equipment and systems for limiting spread of toxic and corrosive fire products | 0.0609 |
P12 | Detection System |
|
| Equipment and systems for detecting fires. | 0.0630 |
P13 | Signal System |
|
| Equipment and systems for transmitting an alarm of fire | 0.0512 |
P14 | Escape Routes | Types of escape routes Dimensions and layout Equipment Linings and floorings | 0.34 0.27 0.16 0.23 | Adequacy and reliability of escape routes | 0.0620 |
P15 | Structure Load Bearing | Load bearing capacity Combustibility | 0.74 0.26 | Structural stability of the building when exposed to a fire | 0.0630 |
P16 | Maintenance & Information | Maintenance of fire safety systems Inspection of escape routes Information | 0.40 0.27 0.33 | Inspection and maintenance of fire safety equipment, escape routes etc. and education of occupants in suppression and evacuation | 0.0601 |
P17 | Ventilation System |
|
|
| 0.0558 |
|
|
|
| SUM | 1.0000 |