Design flood level for the normal case | 250 masl |
Normal operation level for the normal case | 245.5 masl |
Minimum reservoir level for the normal case | 243.8 masl |
Spillway capacity | 4000 m3/s |
No. of bottom outlets | 8 |
Total bottom outlets capacity | 8000 m3/s |
Dam crest level | 312 masl |
Length of the Dam crest | 3730 km |
Crest level of the Concrete Ungated Spillway | 300 masl |
Maximum height of the Concrete Dam | 87 m |
Length of the Concrete Dam | 248 m |
Installed Installed capacity of the power station | 170 Mw |