Number of story

Effect on drift as a result of adding rotation friction dampers at the base of the building on isolated structure %

Effect on drift as a result of adding rotation friction dampers at the ground floor level on isolated structure %

8

Increase (48%)

Almost without change

12

Increase (18%)

Reduction (13%)

16

Increase (27%)

Reduction (8%)

20

Increase (15%)

Reduction (15%)