No. | Laboratory Test | Standards | Results | Spec. Limits |
1 | Penetration at 25˚C, 100 g, 5 Sec. (0.1 mm) | AASHTO: T49-84 | 43.9 | 35 - 50 max. |
2 | Softening Point, (˚C) | AASHTO: T 53 | 50.6 | 50 - 58 max. |
3 | Flush and Fire Point, (˚C) | EN ISO 2592 | 250 | ≥240 |
4 | Specific Gravity | ASTM C 127-88 | 1.028 | Not Specified |
5 | Dynamic Viscosity 60˚C mm2/s | EN 12596 | 235 | ≥225 |
6 | Solubility, % (m/m) | PN-EN 12592 | 100 | ≥99 |
7 | Change of mass, % (m/m) | PN-EN 12607-1 | 0.1 | ≤0.5 |