Test mode | Load-unload | SampleNo. CH6-1600#1 | |
Sample name | CH6-1620 | Minimumforce | 1.96 [mN] |
Test force | 100 [gr] | Holdtimeatload | 5 [sec] |
Loading speed | 1.0 (70.0670 [mN/sec]) | Testcount | 7 |
Hold time at unload | 3 [sec] | Parameter | 20 |
Comment | 20.11.15. CH6-1620 |
|
|
Poisson’s ratio | 0.250 |
|
|
Indenter type | Vickers |
|
|