Tbx

Annealing condition

Tc1 (˚C)

Tc2 (˚C)

x = 0

As-cast

340

520

675˚C

350

530

712˚C

360

540

725˚C

380

540

x = 0.2

As-cast

340

520

675˚C

380

520

712˚C

400

540

725˚C

400

550

x = 0.4

As-cast

340

530

675˚C

370

540

712˚C

400

540

725˚C

420

560

x = 0.6

As-cast

340

530

675˚C

360

530

712˚C

390

540

725˚C

400

580

x = 0.8

As-cast

340

540

675˚C

360

540

712˚C

380

560

725˚C

400

580

x = 1

As-cast

340

540

675˚C

370

550

712˚C

410

560

725˚C

410

560