No. | Parameters | Value |
1 | Installed thermal power, MW | 280* |
2 | Power plant electrical output, MW | 100 |
3 | Lead-bismuth coolant temperature, ˚C · at the outlet from the reactor core · at the inlet to the reactor core |
490 340 |
4 | Reactor core dimensions D × Н, m | 1.645 × 0.9 |
5 | Reactor core mean volumetric power density, kW/dm3 | 140* |
6 | Mean linear load on nuclear fuel elements, kW/m | ~24.3* |
7 | Fuel: · type · uranium-235 charging, % · mean uranium-235 enrichment, % |
UO2 ~1470* ~16.1* |
8 | Reactor core service life, thous. eff. hours | ~53 |
9 | Reloading interval, years | ~8 (~10) |
10 | Volume of lead-bismuth coolant in circuit, м3 | 18 |
11 | Reactor shell overall dimensions, m | ¯ 4.53 × 6.92 |
12 | Primary circuit coolant, volume m3 | Pb-Bi, 32 |
13 | Number of loops | 4 |