(K) | (K) | Heterogeneous fuel assembly calculations | |
NuScale | SBU | ||
(pcm/˚C) | (pcm/˚C) | ||
700 | 410 - 494 | −7.54 ± 0.31 | −5.69 ± 0.18 |
700 | 494 - 505 | −10.79 ± 0.31 | −7.34 ± 0.18 |
700 | 505 - 516 | −12.28 ± 0.31 | −10.13 ± 0.18 |
700 | 516 - 527 | −13.69 ± 0.30 | −9.11 ± 0.18 |
700 | 527 - 538 | −15.47 ± 0.30 | −10.13 ± 0.17 |
700 | 538 - 549 | −15.90 ± 0.30 | −13.84 ± 0.18 |
700 | 549 - 560 | −20.36 ± 0.30 | −14.76 ± 0.18 |
700 | 560 - 571 | −23.06 ± 0.30 | −18.41 ± 0.17 |
700 | 571 - 582 | −28.81 ± 0.30 | −21.92 ± 0.18 |
700 | 582 - 593 | −34.25 ± 0.30 | −26.06 ± 0.18 |