Building Types

Model-1

Model-2

Model-3

Structure Types

Tiers

Tier-1 (Floor―102 m × 102 m) & Height 280.8 m

Tier-1 (Floor―78 m × 78 m) & Height 280.8 m

Tier-1 (Floor―78 m × 78 m) & Height 280.8 m

Shear Walls & Beams

Tier-2 (Floor―78 m × 78 m) & Height 244.8 m

Tier-2 (Floor―54 m × 54 m) & Height 244.8 m

Tier-2 (Floor―54 m × 54 m) & Height 244.8 m

Shear Walls & Beams

Tier-3 (Floor―54 m × 54 m) & Height 208.8 m

Tier-3 (Floor―42 m × 42 m) & Height 208.8 m

Tier-3 (Floor―42 m × 42 m) & Height 104.4 m

Shear Walls & Beams

-

-

Tier-4 (Floor―24 m × 24 m) & Height 104.4 m

Frame Structure

(Columns & Beams)

Aspect Ratio

7.2:1

9.415:1

9.415:1

Drift/Sway:

Allowable limit (H/500) = 1468 mm

726 mm (Acceptable)

996 mm (Acceptable)

992 mm (Acceptable)

Acceleration:

Allowable limit

30 milli-g

18.783 milli-g (Acceptable)

19.586 milli-g (Acceptable)

24.068 milli-g (Acceptable)