Height―ground floor to roof | 3282 feet (1000.8 m) |
Number of stories | 278 |
Building uses (assumed) | Hotel, office and residential |
Frame materials | Concrete structure |
Typical floor live load | 3 kn/m2 (60 psf) |
Basic wind velocity (100 years returned period for Qatar, wind load considered for Qatar) | 41.67 m/sec (150 km/hour) |
Allowable Sway (Drift) [6] -(commentary appendix C-Sec: CC.1.2 ASCE 7-10) | H/500 (H = height of the structure) |
Allowable sway at top of author’s tower | 1000.8 m/500 = 2001.6 mm (6’-6”) |
Sway of the tower at top for dynamic analysis | 1930 mm (6’ - 4”) |
Type of structure | Arrangements of concrete shear walls and beams for Tier-1, Tier-2, Tier-3 and Tier-4. Tier-5 is the frame structure |
Foundation type | Future assignment |
Typical floor height | 3.6 m |
Floor type | R.C.C. Slab |
Shear wall spacing | 12 m, 9 m & 6 m c/c |
Core area | Column-beam framing |
Shear wall thicknesses at ground floor | 1.6 m, 1.5 m, 1.4 m & 1.3 m, gradually decreasing the thicknesses toward top |
Typical beam sizes | Depth 0.8 m, width 1.1 m & 1.2 m |
Column spacing | 6 m (20 feet) c/c |
Column sizes at base | 1.5 m × 1.5 m |
Covered area at base by shear walls & columns | 14.53% |
Concrete strength | Shear walls & columns 80 MPa, beams & slab 40 MPa |
Aspect ratio (building height/least length at base) | 9.8:1 |