Number of fatigue cycles (in ten thousands) | Static stiffness of the vibration isolator with an amplitude of 2 mm (HA) | ||||
F1 | F2 | F3 | F4 | F5 | |
0 | 2614 | 2995 | 3431 | 3673 | 4208 |
10 | 2280 | 2625 | 3002 | 3211 | 3666 |
20 | 2279 | 2602 | 2987 | 3208 | 3670 |
30 | 2284 | 2613 | 2976 | 3225 | 3682 |
40 | 2304 | 2635 | 3002 | 3187 | 3695 |
50 | 2323 | 2657 | 3079 | 3248 | 3729 |
80 | 2328 | 2667 | 3066 | 3255 | 3736 |
110 | 2280 | 2626 | 2984 | 3208 | 3677 |
150 | 2301 | 2653 | 3019 | 3225 | 3707 |
200 | 2288 | 2627 | 3001 | 3258 | 3683 |
Number of fatigue cycles (in ten thousands) | Static stiffness of the vibration isolator with an amplitude of 3 mm (HA) | ||||
F1 | F2 | F3 | F4 | F5 | |
0 | 3012 | 3451 | 3694 | 4232 | 3012 |
10 | 2386 | 2731 | 2911 | 3352 | 2386 |
20 | 2375 | 2708 | 2899 | 3342 | 2375 |
30 | 2410 | 2756 | 2905 | 3401 | 2410 |
40 | 2396 | 2733 | 2915 | 3382 | 2396 |
50 | 2369 | 2710 | 2896 | 3347 | 2369 |
80 | 2377 | 2731 | 2921 | 3364 | 2377 |
110 | 2335 | 2684 | 2869 | 3277 | 2335 |
150 | 2348 | 2702 | 2893 | 3319 | 2348 |
200 | 2344 | 2688 | 2874 | 3303 | 2344 |